May 25, 2018 15:35
6 yrs ago
1 viewer *
English term

\"frequency slow-start\"

English to French Tech/Engineering Energy / Power Generation Gestion des notes de frai
Contexte: "diesel heater"
The system integrates the industry-leading heat controls and frequency slow-start.

Je ne comprends pas "frequency slow-start". La suite du document (plutôt marketing) ne parle ni de "frequency", ni de "slow-start" d'ailleurs.

Quelqu'un aurait-il une idée?

Merci à toutes et à tous

Julien

Discussion

Johannes Gleim May 26, 2018:
@ Julien How is the smooth start effected? Is it controlled by a VFD, a frequency converter, acceleration-rate controller, rotating machinery or any other means, including resistors and/or variable transformers?

Proposed translations

+2
44 mins
Selected

démarrage lent par variateur de fréquence

-

--------------------------------------------------
Note added at 45 minutes (2018-05-25 16:21:03 GMT)
--------------------------------------------------

ll n'y a pas vraiment de progression dans ce processus, ça peut être un démarrage lent ou rapide par variateur de fréquence. D'ailleurs slow = lent....

--------------------------------------------------
Note added at 45 minutes (2018-05-25 16:21:23 GMT)
--------------------------------------------------

slow, c'est un état statique....

--------------------------------------------------
Note added at 48 minutes (2018-05-25 16:24:20 GMT)
--------------------------------------------------

soft start ne veut pas dire slow start

--------------------------------------------------
Note added at 14 heures (2018-05-26 05:56:06 GMT)
--------------------------------------------------

c'est le lien parfait qui indique que démarrage progressif = soft start


"Soft starting
Sanftanlauf
Démarrage progressif
Slow start of a machine when it is first switched on (0.5 -1 second). As a result the restoring torque is strongly reduced during the starting phase. (See also Types of Electronic Control)"
https://www.knowledge21.net/Medien/mdb/data/en/24063/24069/2...


--------------------------------------------------
Note added at 14 heures (2018-05-26 05:56:37 GMT)
--------------------------------------------------

slow start = démarrage lent en toute logique
Peer comment(s):

agree Madeleine van Zanten
15 hrs
agree Michael Confais (X)
576 days
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Selected automatically based on peer agreement."
4 hrs

Demarrage lent en basse fréquence

Le ventilateur du souffleur doit être actionné par un variateur de fréquences qu'on fait tourner à basse vitesse CAD en fréquence basse au début probablement pour ne pas créer de chocs thermiques
Something went wrong...
9 mins

démarrage progressif par variateur de fréquence

Frequency = with variable frequency dribe

voir ici produit similaire:

http://products.wackerneuson.com/manuals/Operators/0192815_0...
"Factory-Installed Options
Variable Frequency Drive (VFD)

The blower motor on your machine requires a surge of electrical current when
starting. This means that the amount of power needed to initially start the motor is
larger than the power required to keep it running. The motor may not start if the
power source does not provide enough current to overcome the surge.
Machines equipped with generators include a Variable Frequency Drive (VFD).
The VFD (a) allows the motor to start at a low RPM with a gradual increase to full
operating speed. This reduces the amount of current needed to start the motor.
...
"The HI750 Heaters are indirect-fired air heaters available in oil (diesel) ..... Start the heater: .... Check the operation of the brakes by braking the vehicle at a slow speed before .... restrictions regarding installation of Indirect-fired (IDF) heaters. ..... Machines equipped with generators include a Variable Frequency Drive (VFD).

--------------------------------------------------
Note added at 51 mins (2018-05-25 16:27:18 GMT)
--------------------------------------------------

"150-WP007A-FR, Dans quels cas utiliser un démarreur progressif ou ...
http://literature.rockwellautomation.com/idc/.../150-wp007_-...
Dans quels cas utiliser un démarreur progressif ou un variateur de fréquence c.a.. Lignes de produit : Démarreurs de moteur intelligent (SMC), variateurs


--------------------------------------------------
Note added at 55 mins (2018-05-25 16:30:36 GMT)
--------------------------------------------------

"Soft starting
Sanftanlauf
Démarrage progressif
Slow start of a machine when it is first switched on (0.5 -1 second). As a result the restoring torque is strongly reduced during the starting phase. (See also Types of Electronic Control)"
https://www.knowledge21.net/Medien/mdb/data/en/24063/24069/2...

--------------------------------------------------
Note added at 56 mins (2018-05-25 16:32:01 GMT)
--------------------------------------------------

variable frequency drive

--------------------------------------------------
Note added at 1 day 3 hrs (2018-05-26 19:27:40 GMT)
--------------------------------------------------

Savez pas lire les références? "Soft starting" = "Slow start ".
"slow, c'est un état statique...." ne veut strictement rien dire.
" VFD (a) allows the motor to start at a low RPM with a gradual increase to full
operating speed.
" dans la référence que j'ai postée. Si vous avez des problèmes de comprehension, je peux vous traduire en français.



Something went wrong...