3 | * |
| ||
1 | почечный |
|
Summary of reference entries provided | |||
---|---|---|---|
comment |
| ||
|
почечный Explanation: проводниковые катетеры могут быть renal standard curve (RSC) и renal double curve (RDC) https://books.google.fr/books?id=NFhgxysdeSAC&pg=PA177&lpg=P... https://daksmed.ru/upload/iblock/fa2/Katalog_TERUMO.pdf https://nda.ru/images/certificates/terumo/terumo_2016-5028.p... https://nevacert.ru/reestry/med-reestr/rzn-2016-5028-17828 |
| |
Login to enter a peer comment (or grade) |
* Explanation: диагностический направляющий катетер для внутренней грудной артерии с длиной, обеспечивающий доступ в почечную артерию (форма у него похожа на RDC) https://emea.cordis.com/content/dam/cordis/web/documents/bro... 3D LIMA 90 Curve сoronarography and angioplasty via right radial approach of left and right internal mammary arteries. Angioplasty of the renal artery using right or left radial approach. https://books.google.ru/books?id=sY9FEAAAQBAJ&pg=PA514&lpg=P... https://www.sciencedirect.com/science/article/pii/S073510971... https://www.dicardiology.com/article/how-perform-transcaval-... Standard 6 French diagnostic guiding catheters are then used (usually renal-shaped work best) -------------------------------------------------- Note added at 1 day 5 hrs (2021-10-23 15:59:04 GMT) -------------------------------------------------- Typically, the access is at the level of the L3-L4 disc space, which we use for geographic landmarks," he explained. -------------------------------------------------- Note added at 1 day 5 hrs (2021-10-23 16:02:33 GMT) -------------------------------------------------- The mean level of bifurcation of the aorta was at the lower third of the body of L4, with the celiac artery, SMA, renal arteries and IMA arising at the level of the T12/L1 intervertebral disc, upper third of the body of L1, lower third of the body of L1 and lower third of the body of L3, respectively. -------------------------------------------------- Note added at 2 days 1 hr (2021-10-24 11:24:08 GMT) -------------------------------------------------- форма дистального конца направляющего катетера должна обеспечивать возможность разворота электрохирургического пакета (проводник-электрод, конвертер-изолятор, микрокатетер-защита) в сторону петли в аорте, а длина соответствовать попаданию в НПВ на уровень почек (L3-L4), где НПВ и аорта рядом и их можно «зараз прожечь» -------------------------------------------------- Note added at 2 days 1 hr (2021-10-24 11:37:43 GMT) -------------------------------------------------- поправка: микрокатетер - для введения в аорту жесткого проводника, по которому доставят TAVR |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
4 hrs |
Reference: comment Reference information: only the one instance of "renal length" so I think this is an error, how would it relate to internal mammary artery? 7f Internal Mammary Guide Catheter (Boston Scientific) | Biozhttps://www.bioz.com › result › product 7f Internal Mammary Guide Catheter, supplied by Boston Scientific, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. -------------------------------------------------- Note added at 4 hrs (2021-10-22 15:01:15 GMT) -------------------------------------------------- Mach 1™ Peripheral Guide Catheter RDC1 - 6Fr x 55cm x .070https://medicalmaterials.com › Catheters Mach 1™ Peripheral Guide Catheter RDC1 - 6Fr x 55cm x .070". Boston Scientific. MSRP: -------------------------------------------------- Note added at 4 hrs (2021-10-22 15:04:42 GMT) -------------------------------------------------- other finding 5 10(K) SUMMARY - Accessdata.fda.govhttps://www.accessdata.fda.gov › pdf13PDF 20 Dec 2013 — catheter assembly and the dilator. ***The guide catheter assembly is the renal access device and has a usable length of 55cm***. -------------------------------------------------- Note added at 4 hrs (2021-10-22 15:05:47 GMT) -------------------------------------------------- Endovascular Interventions: A Case-Based Approachhttps://books.google.co.uk › books Robert S. Dieter, Raymond A. Dieter, Jr., Raymond A. Dieter, III · 2013 · Medical (b) Guide catheter selection is predicated upon angle of the main renal artery in relation with the aorta; commonly used catheters include RDC, RDC1, . |
| |
Login to enter a peer comment (or grade) |
4 hrs |
Reference Reference information: http://www.cardio.by/files/299/Instruktsiya-222-1218.pdf -------------------------------------------------- Note added at 4 hrs (2021-10-22 15:17:52 GMT) -------------------------------------------------- «Специализированный интродъюсер удлиненный (30–45 см) с фиксированной кривизной (RDC, RDC-1, LIMA,IMA, HS, Destination) для катетеризации ПА с проводником диаметром 0,32– 0,35». ИМХО подобранный под длину почки |
| |