5 | fremdspannungsarme (störspannungsfreie) Erdungsklemme |
| ||
3 +1 | "saubere" Erdklemme |
| ||
4 -1 | blanke Erdungsklemme |
|
Discussion entries: 1 | |
---|---|
blanke Erdungsklemme Explanation: Kupferseile und Erdungsseile aus Kupfer werden im Elektroanlagen-Bau zu Erdungszwecken eingesetzt. ... Kupferseil Cu blank, hart. Kupferseil Cu blank, hart - https://shop.faberkabel.de/Starkstromkabel-1-30-kV/Kupfersei... clean ist in diesem Zusammenhang blank |
| |
Login to enter a peer comment (or grade) |
fremdspannungsarme (störspannungsfreie) Erdungsklemme Explanation: By eliminating any form of in-line filtering or active circuitry we maintain the lowest possible AC supply impedance, while a tiny lift in the earth impedance of all but one of the output sockets routes the signal grounds directly to the center of the star and the clean ground terminal. Clearly identified on the casework, this Primary Earth socket is at the center of your system’s performance, literally and metaphorically. http://manuals.audiomania.ru/data/nordost_qbase_qb8_mark_ii.... (hier bedeutet "clean", dass keine Störungen über den Erdungsanschluss eingespeist werden) The isolation transformer (100is1, 100is2, 100is3, 100is4) further comprises: v) a clean ground input terminal (181) for receiving an external clean ground (ISPE); vi) a clean ground output terminal (199) for connecting to a further clean ground input terminal (181) of the further circuit (200, 500), and vii) a physical electrical node (160, 175) placed at a location within the Faraday cage (150) where the magnetic flux and electric field are the lowest. : An important feature of the invention is that the transformer is provided with a separate (extra) input terminal for receiving a clean ground and a separate (extra) output terminal for supplying a clean ground to the further circuit, whereas in the prior art solutions all grounds are connected to each other, i.e. there is no separate low-EMI ground. : The isolation transformer 100is4 receives its clean ground from an external b>clean ground terminal (not shown). https://patents.google.com/patent/WO2019013642A1/en Area Electromagnetic compatibility / Basic concepts IEV ref 161-01-06 en electromagnetic interference EMI degradation in the performance of equipment or transmission channel or a system caused by an electromagnetic disturbance Note 1 to entry: In French, the terms "perturbation électromagnétique" and "brouillage électromagnétique" designate respectively the cause and the effect, and should not be used indiscriminately. Note 2 to entry: In English, the terms "electromagnetic disturbance" and "electromagnetic interference" designate respectively the cause and the effect, and should not be used indiscriminately. de elektromagnetische Störung, f elektromagnetische Funktionsstörung, f https://www.electropedia.org/iev/iev.nsf/display?openform&ie... Area Rotating machinery / Brushes, brush-holders, commutators, slip-rings, terminations IEV ref 411-41-25 en earth terminal. ground terminal (US) a terminal connected to the accessible metal parts of a machine, intended to be connected to an earth or protective conductor de Erdungsklemme (für Maschinen), f https://www.electropedia.org/iev/iev.nsf/display?openform&ie... Area Power capacitors / Technology IEV ref 436-03-02 en earth terminal a terminal intended for connection to earth de -------------------------------------------------- Note added at 22 Stunden (2023-12-15 10:52:18 GMT) -------------------------------------------------- "clean" wird auch für Spannungen und Ströme verwendet, z.B. um oberwellen- und verzerrungsfreie Sinuskurven herhauszufiltern: Clean voltage is crucial to ensuring reliable operation in numerous applications. https://onload.reinhausen.com/en/07-2020/as-simple-as-a-ligh... PowerTrench Technology MOSFETs for clean voltage waveforms and reduced ringing https://www.mouser.de/new/onsemi/fairchild-fdmf6824-drmos/ Supply with clean voltage or arbitrary waveform https://www.zenoneelettronica.it/indexe.html harmonics standards typically assume a completely clean voltage at a PCC. https://www.epri.com/research/programs/053119/results/300202... Thus, an especially clean voltage with low ripple should be used. https://eepower.com/technical-articles/generating-very-low-v... |
| |
Login to enter a peer comment (or grade) |
"saubere" Erdklemme Explanation: Hallo Gerald, es geht dir ja hauptsächlich um das Verständnis des Begriffs, wenn ich richtig mitdenke! Dazu diese Kopie aus https://www.dehn.at/sites/default/files/media/files/blitzpla... "Die Erdungsanlage einer baulichen Anlage muss für alle Erdungsaufgaben gemeinsam verwendet werden, d. h., die Erdungsanlage nimmt alle Aufgaben der Erdung wahr. Andernfalls können Potentialdifferenzen zwischen den an unterschiedlichen Erdungsanlagen geerdeten Einrichtungen auftreten. Früher wurden in der Praxis für die Funktionserdung der Elektronik z. T. eine „saubere Erde“ getrennt von der Blitzschutz- und Schutzerde ausgeführt. Dies ist äußerst ungünstig und kann sogar gefährlich werden. Im Falle von Blitzeinwirkungen treten in der Erdungsanlage sehr große Potentialdifferenzen bis zu einigen 100 kV auf, was zu Zerstörungen von elektronischen Einrichtungen und auch zu Personengefährdungen führen kann. Deshalb fordern die DIN EN 62305-3 und -4 (VDE 0185-305-3 und -4) einen lückenlosen Potentialausgleich innerhalb einer baulichen Anlage." Sowie ein weiteres Beispiel: "Die Funktionserdung dient zur Reduzierung des Hochfrequenzrauschens (RF) und wird auch als **saubere Erdung** bezeichnet. Die Funktionserde dürfen nur zurückfließende RF-Störströme führen. Erdungsschemata müssen eine Funktionserdung enthalten, um Gleichtaktstörungen, die möglicherweise kapazitiv zwischen Kabeln gekoppelt wurden, Einschwingvorgänge am 24-V-Bezugspotenzial oder abgestrahlte Störungen zu minimieren. Die Funktionserde muss von anderen Erden getrennt sein und sollte an einem Punkt mit der Schutzerdung verbunden werden." https://literature.rockwellautomation.com/idc/groups/literat... |
| |
Grading comment
| ||
Login or register (free and only takes a few minutes) to participate in this question. You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy. KudoZ™ translation helpThe KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.