Einhaltung von Luft- und Kriechströmen

English translation: observance of limits for through-air and creepage currents or flash-over currents

GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
German term or phrase:Einhaltung von Luft- und Kriechströmen
English translation:observance of limits for through-air and creepage currents or flash-over currents
Entered by: Johannes Gleim

18:30 Feb 15, 2012
    The asker opted for community grading. The question was closed on 2012-02-19 15:54:10 based on peer agreement (or, if there were too few peer comments, asker preference.)


German to English translations [PRO]
Tech/Engineering - Electronics / Elect Eng / EMC Testing
German term or phrase: Einhaltung von Luft- und Kriechströmen
One task in a list of EMC (electromagnetic compatibility) testing tasks that an accredited testing institute is supposed to carry out (entire task shown above).

Luftstrom - air flow
Kriechstrom - leakage current, current leak

So what is the task, check to make sure they are within acceptable limits, stop them...? Do I have the terms wrong?
Tom Bodine
United States
Local time: 17:58
ofservance of limits for through-air and creepage currents or flash-over currents
Explanation:
I suppose you have a wrong pair of terms. An air flow is non-electrical. What the editor may have meant, is reference to Luft- und Kriechstrecken (distances and creepages).

en clearance
shortest distance in air between two conductive parts
NOTE – This distance applies only to parts that are exposed to the atmosphere and not to parts which are insulated parts or covered with casting compound.
de Luftstrecke, f
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

en creepage distance
shortest distance along the surface of a solid insulating material between two conductive parts
de Kriechstrecke
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

Other possiblity: The editor meant current over surfaces (creepage current) and through air (Überschlag, Durchschlag)

en flashover
electric breakdown between conductors in a gas or a liquid or in vacuum, at least partly along the surface of solid insulation
de Überschlag, m
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

en (electric) breakdown
abrupt change of all or part of an insulating medium into a conducting medium resulting in an electric discharge
de (elektrischer) Durchschlag
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

--------------------------------------------------
Note added at 12 hrs (2012-02-16 07:17:34 GMT)
--------------------------------------------------

Another possible term (for "Fehlerstrom") is current in the fault (through the air gap "Luftspalt").

--------------------------------------------------
Note added at 13 hrs (2012-02-16 07:32:59 GMT)
--------------------------------------------------

Sorry for the typing error, please read "observance of".

--------------------------------------------------
Note added at 2 days19 hrs (2012-02-18 13:35:11 GMT)
--------------------------------------------------

Clearance
The shortest distance between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured through air.

Creepage Distance
The shortest path between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured along the surface of the insulation.
http://www.i-spec.com/IEC_60950/glossary.html

UL 1059 “Terminal Blocks”
In order for Phoenix Contact products to be able to be
used industrial applications without restrictions, they are
generally tested and recognized in accordance with UL 1059.
The following table lists the clearances and creepage distances
required for the components.
Damit die Phoenix Contact-Produkte ohne jegliche Einschränkung
in industriellen Anwendungen eingesetzt werden können,
werden sie überwiegend nach UL 1059 geprüft und anerkannt
In der nachfolgenden Tabelle sind die darin geforderten Luftund
Kriechstrecken für die Komponenten aufgelistet:
Ein Unterschreiten der im Gerätestandard geforderten Luftstrecken
ist dann zulässig, wenn das Endgerät eine in der UL 840 (Tabelle 7.1) beschriebenen Stoßspannungsprüfungen ohne Überschlag besteht. Die Höhe der Stoßspannung richtet sich nach der im Produktstandard geforderten Luftstrecke.
(Anmerkung: Je nach Markierung wird der enlische Vordergrungtext oder der deutsche unsichtbar gemachte Hintergrundtext kopiert)
http://www2.phoenixcontact.com/local_pdf/tr_TR/Connectors_Po...

5. LED "Isolationsfehler": Leuchtet, wenn bei eingeschalteter Hochspannung ein Überschlag stattgefunden hat.
:
5.2 Spannungsprüfungen nach DIN VDE 0113 / EN 60204
Um die Luft- und Kriechstrecken zu überprüfen, muss die elektrische Ausrüstung von Maschinen einer Prüfspannung mindestens 1 Sekunde standhalten.
:
5. LED "INSULATION BREAK DOWN": Indicates when a spark-over has taken place during test.
:
5.2. Voltage Tests in Compliance with EN 60204 / DIN VDE 0113
To test creepage and clearance distances, the electrical equipment must withstand a test voltage for at least 1 second.
http://www.pewa.de/DATENBLATT/DBL_BEHA_9030D_MANUAL_DEUTSCH....

Sie erkennen frühzeitig Fehler im laufenden Produktionsprozess; dies beginnt bereits bei der Analyse von Großsignaleigenschaften bis hin zur Identifikation von Fehlerfällen, wie z.B. Überschlag und Kurzschluss.
[...] errors at an early point of time within the running production process starting with the analysis of large signal characteristics up to the identification of error cases such as flashovers or short circuit.
scienlab.de
http://www.linguee.de/deutsch-englisch/uebersetzung/satter k...

Luftüberschlag arc flash
http://www.proz.com/glossary-translations/german-to-english-...

1. Überspannungsschutzeinrichtung (1), mit einer ein erstes Funkenhorn (3) aufweisenden ersten Elektrode
(2), mit einer ein zweites Funkenhorn (5) aufweisenden zweiten Elektrode (4), mit einer zwischen den Funkenhörnern (3, 5) wirksamen Luft- Durchschlag-Funkenstrecke (6) und mit einem die Elektroden (2, 4) aufnehmenden Gehäuse (7),…
:
1. Overvoltage protection device (1) with a first electrode (2) which has a first arcing horn (3), with a second electrode (4) which has a second arcing horn (5), with an air-breakdown spark gap (6) which is active between the arcing horns (3, 5), and with a housing (7) …
https://data.epo.org/publication-server/pdf-document?PN=EP10...

Some terms from a technical dictionary, in addition:

Durchschlag m bei Stoßspannung impulse breakdown; dieleletrischer dielectric breakdown; eines Funkens striking of a spark; elektrischer electrical breakdown

Luftdurchschlag m air beakdow [spark over]

Luftstrecke f cearance (IEC 50-441-17-31)

Überschlag n 1. arc-over, spark-over, flasch-over, break-over (z.b. Funken, Lichtbogen;

Überschlagprüfung f flash-over test[ing], spark-over test[ing]

Überschlagstrecke f spark-over path {distance], flash-over distance [path]



--------------------------------------------------
Note added at 2 days19 hrs (2012-02-18 13:38:39 GMT)
--------------------------------------------------

Sorry for the typing errors; please read 'flash' instead of 'flasch' and dielektrischer instead of 'dieletrischer'
The terms have been takten from Budig, Fachwörterbuch Elektrotechnik und Elektronik, Deutsch - Englisch.
Selected response from:

Johannes Gleim
Local time: 02:58
Grading comment
Thanks. You all pretty much finally arrived at the same conclusion, but this was the first answer in that direction; they meant "-strecken" not "-strömen". I woud divide up the points but don't know how, so am leaving it to the community.
4 KudoZ points were awarded for this answer



Summary of answers provided
4maintenance of
Richard Stephen
3meet air and creepage distance requirements
Bernd Runge
3Einhaltung von Luft- und Kriechstrecken
Randall Nall
3ofservance of limits for through-air and creepage currents or flash-over currents
Johannes Gleim


Discussion entries: 4





  

Answers


13 mins   confidence: Answerer confidence 4/5Answerer confidence 4/5
maintenance of


Explanation:
air flow and leakage current values/tolerances

--------------------------------------------------
Note added at 16 mins (2012-02-15 18:47:14 GMT)
--------------------------------------------------

Wait a minute; its probably not 'air flow' - rather current flow across an air gap

Richard Stephen
United States
Local time: 18:58
Specializes in field
Native speaker of: Native in EnglishEnglish
PRO pts in category: 304

Peer comments on this answer (and responses from the answerer)
neutral  Johannes Gleim: cannot be maintenance, as Einhalten means not exceeding limits. Maintenance means to warrant a minimum current. You should say "maintenance of upper limits for fault currents"
12 hrs
  -> Perhaps you should look up the definition of maintenance - it has a great deal more meanings than 'Wartung' - You also 'maintain' tolerances - which was my suggestion.
Login to enter a peer comment (or grade)

12 hrs   confidence: Answerer confidence 3/5Answerer confidence 3/5
Einhaltung von Luft- und Kriechstrecken
meet air and creepage distance requirements


Explanation:
Gemäß IEC 60079-7:2006

Man könnte air distance auch durch clearance ersetzen.
Clearance
The shortest distance between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured through air.

Creepage Distance
The shortest path between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured along the surface of the insulation.

http://www.i-spec.com/IEC_60950/glossary.html

Bernd Runge
Germany
Local time: 02:58
Specializes in field
Native speaker of: Native in GermanGerman
PRO pts in category: 318
Login to enter a peer comment (or grade)

15 hrs   confidence: Answerer confidence 3/5Answerer confidence 3/5
Einhaltung von Luft- und Kriechstrecken


Explanation:
“Do I have the terms wrong?”

I asked my contacts at Siemens on your behalf. They told me the correct German should be: Einhaltung von Luft- und Kriechstrecken, just as Bernd quietly observes in his changing of the source term.

Randall Nall
Local time: 02:58
Native speaker of: English
Login to enter a peer comment (or grade)

12 hrs   confidence: Answerer confidence 3/5Answerer confidence 3/5
ofservance of limits for through-air and creepage currents or flash-over currents


Explanation:
I suppose you have a wrong pair of terms. An air flow is non-electrical. What the editor may have meant, is reference to Luft- und Kriechstrecken (distances and creepages).

en clearance
shortest distance in air between two conductive parts
NOTE – This distance applies only to parts that are exposed to the atmosphere and not to parts which are insulated parts or covered with casting compound.
de Luftstrecke, f
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

en creepage distance
shortest distance along the surface of a solid insulating material between two conductive parts
de Kriechstrecke
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

Other possiblity: The editor meant current over surfaces (creepage current) and through air (Überschlag, Durchschlag)

en flashover
electric breakdown between conductors in a gas or a liquid or in vacuum, at least partly along the surface of solid insulation
de Überschlag, m
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

en (electric) breakdown
abrupt change of all or part of an insulating medium into a conducting medium resulting in an electric discharge
de (elektrischer) Durchschlag
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...

--------------------------------------------------
Note added at 12 hrs (2012-02-16 07:17:34 GMT)
--------------------------------------------------

Another possible term (for "Fehlerstrom") is current in the fault (through the air gap "Luftspalt").

--------------------------------------------------
Note added at 13 hrs (2012-02-16 07:32:59 GMT)
--------------------------------------------------

Sorry for the typing error, please read "observance of".

--------------------------------------------------
Note added at 2 days19 hrs (2012-02-18 13:35:11 GMT)
--------------------------------------------------

Clearance
The shortest distance between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured through air.

Creepage Distance
The shortest path between two conductive parts, or between a conductive part and the bounding surface of the equipment, measured along the surface of the insulation.
http://www.i-spec.com/IEC_60950/glossary.html

UL 1059 “Terminal Blocks”
In order for Phoenix Contact products to be able to be
used industrial applications without restrictions, they are
generally tested and recognized in accordance with UL 1059.
The following table lists the clearances and creepage distances
required for the components.
Damit die Phoenix Contact-Produkte ohne jegliche Einschränkung
in industriellen Anwendungen eingesetzt werden können,
werden sie überwiegend nach UL 1059 geprüft und anerkannt
In der nachfolgenden Tabelle sind die darin geforderten Luftund
Kriechstrecken für die Komponenten aufgelistet:
Ein Unterschreiten der im Gerätestandard geforderten Luftstrecken
ist dann zulässig, wenn das Endgerät eine in der UL 840 (Tabelle 7.1) beschriebenen Stoßspannungsprüfungen ohne Überschlag besteht. Die Höhe der Stoßspannung richtet sich nach der im Produktstandard geforderten Luftstrecke.
(Anmerkung: Je nach Markierung wird der enlische Vordergrungtext oder der deutsche unsichtbar gemachte Hintergrundtext kopiert)
http://www2.phoenixcontact.com/local_pdf/tr_TR/Connectors_Po...

5. LED "Isolationsfehler": Leuchtet, wenn bei eingeschalteter Hochspannung ein Überschlag stattgefunden hat.
:
5.2 Spannungsprüfungen nach DIN VDE 0113 / EN 60204
Um die Luft- und Kriechstrecken zu überprüfen, muss die elektrische Ausrüstung von Maschinen einer Prüfspannung mindestens 1 Sekunde standhalten.
:
5. LED "INSULATION BREAK DOWN": Indicates when a spark-over has taken place during test.
:
5.2. Voltage Tests in Compliance with EN 60204 / DIN VDE 0113
To test creepage and clearance distances, the electrical equipment must withstand a test voltage for at least 1 second.
http://www.pewa.de/DATENBLATT/DBL_BEHA_9030D_MANUAL_DEUTSCH....

Sie erkennen frühzeitig Fehler im laufenden Produktionsprozess; dies beginnt bereits bei der Analyse von Großsignaleigenschaften bis hin zur Identifikation von Fehlerfällen, wie z.B. Überschlag und Kurzschluss.
[...] errors at an early point of time within the running production process starting with the analysis of large signal characteristics up to the identification of error cases such as flashovers or short circuit.
scienlab.de
http://www.linguee.de/deutsch-englisch/uebersetzung/satter k...

Luftüberschlag arc flash
http://www.proz.com/glossary-translations/german-to-english-...

1. Überspannungsschutzeinrichtung (1), mit einer ein erstes Funkenhorn (3) aufweisenden ersten Elektrode
(2), mit einer ein zweites Funkenhorn (5) aufweisenden zweiten Elektrode (4), mit einer zwischen den Funkenhörnern (3, 5) wirksamen Luft- Durchschlag-Funkenstrecke (6) und mit einem die Elektroden (2, 4) aufnehmenden Gehäuse (7),…
:
1. Overvoltage protection device (1) with a first electrode (2) which has a first arcing horn (3), with a second electrode (4) which has a second arcing horn (5), with an air-breakdown spark gap (6) which is active between the arcing horns (3, 5), and with a housing (7) …
https://data.epo.org/publication-server/pdf-document?PN=EP10...

Some terms from a technical dictionary, in addition:

Durchschlag m bei Stoßspannung impulse breakdown; dieleletrischer dielectric breakdown; eines Funkens striking of a spark; elektrischer electrical breakdown

Luftdurchschlag m air beakdow [spark over]

Luftstrecke f cearance (IEC 50-441-17-31)

Überschlag n 1. arc-over, spark-over, flasch-over, break-over (z.b. Funken, Lichtbogen;

Überschlagprüfung f flash-over test[ing], spark-over test[ing]

Überschlagstrecke f spark-over path {distance], flash-over distance [path]



--------------------------------------------------
Note added at 2 days19 hrs (2012-02-18 13:38:39 GMT)
--------------------------------------------------

Sorry for the typing errors; please read 'flash' instead of 'flasch' and dielektrischer instead of 'dieletrischer'
The terms have been takten from Budig, Fachwörterbuch Elektrotechnik und Elektronik, Deutsch - Englisch.

Johannes Gleim
Local time: 02:58
Specializes in field
Native speaker of: German
PRO pts in category: 449
Grading comment
Thanks. You all pretty much finally arrived at the same conclusion, but this was the first answer in that direction; they meant "-strecken" not "-strömen". I woud divide up the points but don't know how, so am leaving it to the community.
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.